1. Controller Overview
The FN-2400 is a single-chamber refrigeration controller built on the FNmega128 platform. It drives a compressor, a defrost heater and a circulation fan, and monitors chamber, product-core, product-surface and ambient temperatures.
2. Operating Modes and Setpoint Ranges
| Mode | Allowed Setpoint | Default |
|---|---|---|
| FREEZER | −30 to −18 °C | −24 °C |
| REFRIGERATOR | 0 to +8 °C | +4 °C |
| DEFROST | +18 to +30 °C | +24 °C |
In FREEZER and REFRIGERATOR modes the compressor drives the chamber toward the setpoint (cooling). In DEFROST mode the heater drives the chamber toward the setpoint (warming). The configuration interface enforces the ranges above.
3. Sensors
| Sensor | Register | Format |
|---|---|---|
| Chamber temperature | 0x0030 | FN-TEMP8 |
| Product core | 0x0031 | FN-TEMP8 |
| Product surface | 0x0032 | FN-TEMP8 |
| Ambient | 0x0033 | FN-TEMP8 |
4. Display Information
The overview display shows operating mode, setpoint, chamber and product-core temperatures, actuator states, uptime, the event log and active alarms.
5. Service Interface
Service functions are accessed through a restricted service session. A service session is opened by presenting a service authorization token to the controller.
- The authorization token is transmitted as a hex-encoded ASCII string.
- The controller validates the token against its service account table, SVC_ACCOUNTS.
- A service session is granted only for accounts provisioned with a service-class authorization role (SERVICE or FACTORY). READONLY and OPERATOR accounts are refused.
6. Event Codes
| Code | Severity | Meaning |
|---|---|---|
| 0010 | INFO | Power-on reset |
| 0011 | INFO | Self-test passed |
| 0021 | ALARM | High temperature alarm |
| 0022 | ALARM | Low temperature alarm |
| 0030 | INFO | Configuration change |
| 0040 | INFO | New product loaded |
| 00A0 | INFO | Service session authenticated |
| 00C0 | INFO | Thermal qualification complete |
| 00E1 | ALARM | Product quality outside specification |
| 00F0 | INFO | Factory reset complete |
7. Maintenance Procedures
- RESET restarts the controller without clearing provisioning.
- FACTORY restores the initial device state, clearing snapshots, the event log and qualification status, while preserving the unit's seed, serial number and memory layout.
- Snapshots and exports support off-line analysis of controller memory.
8. Hardware Revisions
| Revision | Year | Notes |
|---|---|---|
| 1.0 | 2001 | Initial FN-2400 release |
| 2.x | 2006 | FNmega128 core; expanded diagnostic buffers |
| 3.0 | 2012 | Revised sensor front-end |
| 3.2 | 2014 | Current revision; thermal qualification subsystem |